Ceramic Pressure Transmitter
Details
Product Parameters
Cases
Download
Strong corrosion resistance: Ceramics have excellent resistance to most acids, alkalis, salts, and other chemical media, making them suitable for long-term use in corrosive environments.
High hygiene performance: The ceramic surface is smooth, not prone to impurity adhesion, and easy to clean, meeting the hygiene standards of the food and pharmaceutical industries.
Good stability: Ceramics have a low coefficient of thermal expansion and are minimally affected by temperature changes, ensuring measurement accuracy.
Model | HDP508 |
Power Supply | 8~32VDC |
Measured Medium | Oil, water, gas and other media incompatible with 316 stainless steel |
Enclosure Protection | IP65, IP67, IP68 |
Compensation Temperature | -20~70℃ |
Long-term Stability | ±0.2%F.S/y |
Natural Frequency | 5KHZ~650kHz |
Overload Pressure | 150%F.S |
Pressure Type | Gauge Pressure, Absolute Pressure, Sealed Pressure |
Measurement Range | -100kPa~0...10kPa~10MPa |
Zero Temperature Drift | ±1%FS (Within Temperature Compensation Range) |
Comprehensive Accuracy | Class 0.1 / Class 0.25 |
Operating Temperature | -20~85℃ |
Process Connection | Threaded Connection / Sanitary Connection / |
Medium Temperature | -20~85℃ |